Hydroflam® TN12
Hydroflam® TN12 is a flame retardant that delays ignition and limits the spread of flames in fabrics of natural origin such as cotton, burlap, velvet, damask, muslin, etc.
Its exceptional effectiveness requires small quantities. Its penetration capacity is very strong and facilitates its application.
Cotton: M1 classification according to NF P92-512 standard. FCBA
Linen PV: M1 classification according to NF P92-512 standard. PV du FCBA
Protecflam Industries also offers to fireproof your supports in our workshops, do not hesitate to contact us for any request or quote.
Choose your packaging
Hydroflam® TN12 is available in liquid form (without VOCs or formaldehyde), odourless and colourless. It is ready to use. It can be coloured (powder dye or liquid acrylic) to obtain an aesthetic effect or traceability. The fireproof material, once dry, can be tinted but only with non-degrading products.
Prevents the spread of flames and fire and reduces the development of smoke.
Must be used in dry and closed indoor rooms.
Installation and preparation of the substrate
The substrate must be dry, free of dust, oil, wax, grease, dirt, resin, etc.
Hydroflam® TN12 can be applied in 3 ways on dry, porous substrate, double-sided:
- By “refusal” spraying with a flat jet nozzle.
- By soaking (total immersion in the flame retardant).
- By scarfing (pay-off rate according to other treatments and desired results).
It is advisable to let it dry between 12 and 72 hours depending on the temperature and humidity, in a natural or accelerated way. A slight shrinkage of the fiber may occur.
Indicative returns
The consumption of Hydroflam® TN12 varies according to the nature, composition, mass of the substrate and the target fire classification. In general, the carrying rate of Hydroflam® TN12 must be around 30% of the mass of the substrate to be treated.
For example, to fire retardant a 200 g cotton fabric, 60 g of Hydroflam® TN12 will be required. The mass of the wet fabric before drying must be 260 g.
Protect against frost!
-
Made in France
Some of our flame-retardant solutions are manufactured in France, at our factories in Loire-Atlantique, drawing on our expertise and in-house R&D department. This expertise enables us to refine our formulations and meet specific requirements.
-
Tests and performance
Our solutions are tested by accredited laboratories in accordance with current standards and protocols. The results of these tests are used to draw up technical documents certifying the performance and fire resistance of the products in question.
-
Technical Expertise
For over 25 years, Protecflam has been developing its expertise in the field of passive fire protection and the fire retardancy treatment of a wide range of materials. This experience enables us to support each project with an approach tailored to its specific requirements.
-
Personalized Support
From identifying your requirements to selecting the most suitable solution, our team is here to support you with your flame-retardant treatment projects. Whether it’s a workshop-based treatment or an on-site service, we tailor our approach to the specific requirements of your project.