Fireproofing and fire regulations

Fireproofing and fire regulations

Fireproofing and fire regulations

Concerning these two standards, the European Euroclasses standards concern building materials and floor coverings for the whole of the European community, but the French standards, namely the “M” classification, remain valid for landscaping and decoration materials. There is an indicative correlation table that can only be read from left to right.

The Euroclass classification is a European evaluation system for construction products and materials. There are several categories in reaction and resistance to fire.

In reaction to fire, there are 3 main categories:

The French M classification (for Materials) remains a system in force for decorative materials and products.

Protecflam Industries provides you with solutions to meet these regulations:

In supply of fire retardant products (direct manufacturer),

Summarised table of Euroclasses

Other materials (decorations and temporary protections)

TestingAccording to NF series P 92 500Requirements
Rigid or rendered rigid materials with a thickness of less than 5 mmReaction to Fire Test
NF P 92-501
M Rating:
M0-M1-M2-M3-M4
Flexible materials with a thickness of less than 5 mmReaction to Fire Test
NF P 92-503
M Rating:
M0-M1-M2-M3-M4
Flexible materials (Flame spread measurement)Reaction to Fire Test
NF P 92-504
M Rating:
M0-M1-M2-M3-M4
Hot melt materials (drop test)Reaction to Fire Test
NF P 92-505
M0-M1-M2-M3-M4
Floor coverings Radiant panel testReaction to Fire Test
NF P 92-506
M Rating:
M0-M1-M2-M3-M4

Comments: Furnishing materials not covered by the DPC. These materials include: decoration, furniture, curtains and curtains, paint. They retain the old French “M” classification (reference to the standards of the NF p 92 500 series).

Construction products other than floor coverings

TestingClasses according to NF en 13 501-1Requirements
Non-combustibility (NF EN ISO 1182)
PCS (NF EN 716)
A1Non-combustible
Non-combustibility (NF EN ISO 1182)
PCS (NF EN 716)
SBI (NF EN 13823)
A2S1
S1
S2
S3
d0
d1
d0
d1
M0
SBI (NF EN 13823)
Small flame (NF EN 11925-2)
BS1
S1
S2

d0
d1
M1
SBI (NF EN 13823)
Small flame (NF EN 11925-2)
CS1
S1
S2

d0
d1
M2
SBI (NF EN 13823)
Small flame (NF EN 11925-2)
DS1
S1
S2
d0
d1
M3M4 – non-dripping
SBI (NF EN 13823)
Small flame (NF EN 11925-2)
E–d1M4
SBI (NF EN 13823)
Small flame (NF EN 11925-2)
E–D2No ranking
SBI (NF EN 13823)
Small flame (NF EN 11925-2)
F––No ranking

Comments: Classes A1 and A2, A2, A1fl and A2fls1 are assigned to very low-combustible products and correspond to the French class M0; in no case is there any equivalence between the Euroclass and M fire classifications, but only the degrees of own performance are classified in a hierarchical manner. They then give fire performance indicators without a comparative scale with each other.

Classes B to E, and Bfl to Dfl apply to combustible products formerly M1 to M4;

The Euroclasses provide for additional classifications:

Flooring

TestingClassified according to NF EN 13 501-1Requirements
Non-combustibility (NF EN ISO 1182)
PCS (NF EN 716)
A1flNon-combustible
Non-combustibility (NF EN ISO 1182)
PCS (NF EN 716)
SBI (NF EN 13823)
A2fl
A2fl
S1
S2
M0
M3
SBI (NF EN 13823)
Small flame (NF EN 11925-2)
BflS1
S2
M3
SBI (NF EN 13823)
Small flame (NF EN 11925-2)
CflS1
S2
M3
SBI (NF EN 13823)
Small flame (NF EN 11925-2)
DFLS1
S2
M4
Small flame (NF EN 11925-2)Efl…

Acronyms used

ISO: International Organization for Standardization
EN: European Standard
NF: French Standard
CPD: Construction Products Directive
PCS: Superior Calorific Value
SBI: Single Burning Item
OJEC: Official Journal of the European Communities
ATE: European Technical Approval
ERP: Establishment open to the public
EU: European Union
fl : Floor