 {"id":3111,"date":"2026-06-24T16:46:21","date_gmt":"2026-06-24T14:46:21","guid":{"rendered":"https:\/\/protecflam.preprod-kalelia.fr\/guides\/fireproofing-and-fire-regulations\/"},"modified":"2026-09-22T11:55:04","modified_gmt":"2026-09-22T09:55:04","slug":"fireproofing-and-fire-regulations","status":"publish","type":"guides","link":"https:\/\/protecflam.com\/en\/guides\/fireproofing-and-fire-regulations\/","title":{"rendered":"Fireproofing and fire regulations"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Concerning these two standards, the European Euroclasses standards concern building materials and floor coverings for the whole of the European community, but the French standards, namely the &#8220;M&#8221; classification, remain valid for landscaping and decoration materials. There is an indicative correlation table that can only be read from left to right.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>The Euroclass classification<\/strong> is a European evaluation system for construction products and materials. There are several categories in <strong>reaction<\/strong> and <strong>resistance<\/strong> to fire.<\/p>\n\n<p class=\"wp-block-paragraph\">In <strong>reaction to fire<\/strong>, there are 3 main categories:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>Walls  Ceilings<\/li>\n\n\n\n<li>Floor<\/li>\n\n\n\n<li>Roof<\/li>\n<\/ul>\n\n<p class=\"wp-block-paragraph\">The French M classification (for Materials) remains a system in force for decorative materials and products.<\/p>\n\n<p class=\"wp-block-paragraph\"><strong>Protecflam Industries<\/strong> provides you with solutions to meet these regulations:<\/p>\n\n<p class=\"wp-block-paragraph\">In supply of <strong>fire retardant products<\/strong> (direct manufacturer),<\/p>\n\n<ul class=\"wp-block-list\">\n<li>by processing your materials in its workshops,<\/li>\n\n\n\n<li>by coming to treat on your site,<\/li>\n\n\n\n<li>by providing you with:\n<ul class=\"wp-block-list\">\n<li>M1 flame-retardant plastic films, M1<\/li>\n\n\n\n<li>or Euroclass B ultra-thin fibreboard, M1 or Euroclass B,<\/li>\n\n\n\n<li>semi-rigid M1 polypropylene sheets,<\/li>\n\n\n\n<li>M1 flame retardant adhesives<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>by offering you tailor-made products according to your specifications.<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">Summarised table of Euroclasses<\/h2>\n\n<p class=\"wp-block-paragraph\"><strong>Other materials (decorations and temporary protections)<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Testing<\/strong><\/td><td><strong>According to NF series P 92 500<\/strong><\/td><td><strong>Requirements<\/strong><\/td><\/tr><tr><td>Rigid or rendered rigid materials with a thickness of less than 5 mm<\/td><td>Reaction to Fire Test<br\/>NF P 92-501<\/td><td>M Rating:<br\/>M0-M1-M2-M3-M4<\/td><\/tr><tr><td>Flexible materials with a thickness of less than 5 mm<\/td><td>Reaction to Fire Test<br\/>NF P 92-503<\/td><td>M Rating:<br\/>M0-M1-M2-M3-M4<\/td><\/tr><tr><td>Flexible materials (Flame spread measurement)<\/td><td>Reaction to Fire Test<br\/>NF P 92-504<\/td><td>M Rating:<br\/>M0-M1-M2-M3-M4<\/td><\/tr><tr><td>Hot melt materials (drop test)<\/td><td>Reaction to Fire Test<br\/>NF P 92-505<\/td><td>M0-M1-M2-M3-M4<\/td><\/tr><tr><td>Floor coverings Radiant panel test<\/td><td>Reaction to Fire Test<br\/>NF P 92-506<\/td><td>M Rating:<br\/>M0-M1-M2-M3-M4<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>Comments:<\/strong> Furnishing materials not covered by the DPC. These materials include: decoration, furniture, curtains and curtains, paint. They retain the old French &#8220;M&#8221; classification (reference to the standards of the NF p 92 500 series).<\/p>\n\n<h2 class=\"wp-block-heading\">Construction products other than floor coverings<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Testing<\/strong><\/td><td colspan=\"3\"><strong>Classes according to NF en 13 501-1<\/strong><\/td><td><strong>Requirements<\/strong><\/td><\/tr><tr><td>Non-combustibility (NF EN ISO 1182)<br\/>PCS (NF EN 716)<\/td><td>A1<\/td><td><\/td><td><\/td><td>Non-combustible<\/td><\/tr><tr><td>Non-combustibility (NF EN ISO 1182)<br\/>PCS (NF EN 716)<br\/>SBI (NF EN 13823)<\/td><td>A2<\/td><td>S1<br\/>S1<br\/>S2<br\/>S3<\/td><td>d0<br\/>d1<br\/>d0<br\/>d1<\/td><td>M0<\/td><\/tr><tr><td>SBI (NF EN 13823)<br\/>Small flame (NF EN 11925-2)<\/td><td>B<\/td><td>S1<br\/>S1<br\/>S2<\/td><td><br\/>d0<br\/>d1<\/td><td>M1<\/td><\/tr><tr><td>SBI (NF EN 13823)<br\/>Small flame (NF EN 11925-2)<\/td><td>C<\/td><td>S1<br\/>S1<br\/>S2<\/td><td><br\/>d0<br\/>d1<\/td><td>M2<\/td><\/tr><tr><td>SBI (NF EN 13823)<br\/>Small flame (NF EN 11925-2)<\/td><td>D<\/td><td>S1<br\/>S1<br\/>S2<\/td><td>d0<br\/>d1<br\/><\/td><td>M3M4 &#8211; non-dripping <\/td><\/tr><tr><td>SBI (NF EN 13823)<br\/>Small flame (NF EN 11925-2)<\/td><td>E<\/td><td>&#8211;<\/td><td>d1<\/td><td>M4<\/td><\/tr><tr><td>SBI (NF EN 13823)<br\/>Small flame (NF EN 11925-2)<\/td><td>E<\/td><td>&#8211;<\/td><td>D2<\/td><td>No ranking<\/td><\/tr><tr><td>SBI (NF EN 13823)<br\/>Small flame (NF EN 11925-2)<\/td><td>F<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>No ranking<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>Comments:<\/strong> Classes A1 and A2, A2, A1fl and A2fls1 are assigned to very low-combustible products and correspond to the French class M0; <strong>in no case<\/strong> is there any equivalence between the <strong>Euroclass and M fire classifications<\/strong>, but only the degrees of own performance are classified in <strong>a hierarchical manner. They then give fire performance indicators without a comparative scale with each other.<\/strong> <\/p>\n\n<p class=\"wp-block-paragraph\">Classes B to E, and Bfl to Dfl apply to combustible products formerly M1 to M4;<\/p>\n\n<p class=\"wp-block-paragraph\">The Euroclasses provide for additional classifications:<\/p>\n\n<ul class=\"wp-block-list\">\n<li>s (1,2,3) for the production of smoke (S).<\/li>\n\n\n\n<li>D (0,1,2) for the fall of drops and flaming debris (d for &#8220;drop&#8221;).<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">Flooring<\/h2>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Testing<\/strong><\/td><td colspan=\"2\"><strong>Classified according to NF EN 13 501-1<\/strong><\/td><td><strong>Requirements<\/strong><\/td><\/tr><tr><td>Non-combustibility (NF EN ISO 1182)<br\/>PCS (NF EN 716)<\/td><td>A1fl<\/td><td><\/td><td>Non-combustible<\/td><\/tr><tr><td>Non-combustibility (NF EN ISO 1182)<br\/>PCS (NF EN 716)<br\/>SBI (NF EN 13823)<\/td><td>A2fl<br\/>A2fl<\/td><td>S1<br\/>S2<\/td><td>M0<br\/>M3<\/td><\/tr><tr><td>SBI (NF EN 13823)<br\/>Small flame (NF EN 11925-2)<\/td><td>Bfl<\/td><td>S1<br\/>S2<\/td><td>M3<\/td><\/tr><tr><td>SBI (NF EN 13823)<br\/>Small flame (NF EN 11925-2)<\/td><td>Cfl<\/td><td>S1<br\/>S2<\/td><td>M3<\/td><\/tr><tr><td>SBI (NF EN 13823)<br\/>Small flame (NF EN 11925-2)<\/td><td>DFL<\/td><td>S1<br\/>S2<\/td><td>M4<\/td><\/tr><tr><td>Small flame (NF EN 11925-2)<\/td><td>Efl<\/td><td><\/td><td>&#8230;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<p class=\"wp-block-paragraph\"><strong>Acronyms used<\/strong><\/p>\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>ISO:<\/strong> International Organization for Standardization<br\/><strong>EN:<\/strong> European Standard<br\/><strong>NF:<\/strong> French Standard<br\/><strong>CPD:<\/strong> Construction Products Directive<br\/><strong>PCS:<\/strong> Superior Calorific Value<br\/><strong>SBI:<\/strong> Single Burning Item<\/td><td><strong>OJEC:<\/strong> Official Journal of the European Communities<br\/><strong>ATE:<\/strong> European Technical Approval<br\/><strong>ERP:<\/strong> Establishment open to the public<br\/><strong>EU:<\/strong> European Union<br\/><strong>fl :<\/strong> Floor<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"featured_media":3282,"template":"","type_guide":[290,291],"class_list":["post-3111","guides","type-guides","status-publish","has-post-thumbnail","hentry","type_guide-fire-resistance-of-materials","type_guide-fire-safety-standards-and-regulations"],"_links":{"self":[{"href":"https:\/\/protecflam.com\/en\/wp-json\/wp\/v2\/guides\/3111","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/protecflam.com\/en\/wp-json\/wp\/v2\/guides"}],"about":[{"href":"https:\/\/protecflam.com\/en\/wp-json\/wp\/v2\/types\/guides"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/protecflam.com\/en\/wp-json\/wp\/v2\/media\/3282"}],"wp:attachment":[{"href":"https:\/\/protecflam.com\/en\/wp-json\/wp\/v2\/media?parent=3111"}],"wp:term":[{"taxonomy":"type_guide","embeddable":true,"href":"https:\/\/protecflam.com\/en\/wp-json\/wp\/v2\/type_guide?post=3111"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}